The LS10D Surgical Energy Platform is a multi-function electrosurgical generator that brings intelligent vessel sealing together with a complete range of monopolar and bipolar outputs. With 10 working modes and a smart circular recognition interface, it provides one reliable energy source for cutting, coagulation and haemostasis across open, laparoscopic and endoscopic procedures.
The dedicated vessel-sealing mode seals arteries, veins and tissue bundles up to 7 mm in diameter. The circular LigaSure interface recognises the connected sealing instrument and selects the appropriate algorithm automatically. During activation, the generator monitors tissue impedance in real time and ends the cycle once the vessel wall is fully fused, then signals completion audibly. The result is a permanent, repeatable seal without clips or ties, with limited thermal spread to adjacent tissue.
Key benefit: Reliable haemostasis of vessels up to 7 mm with a single activation — no instrument change, no mechanical ligation.
Monopolar Cutting
Waveform | Rated Power | Typical Use |
|---|---|---|
Pure Cut | 300 W | Fast, clean tissue division with minimal haemostasis |
Blend Cut | 200 W | Cutting with simultaneous coagulation |
Monopolar Coagulation
Waveform | Rated Power | Typical Use |
|---|---|---|
Soft Coagulation | 120 W | Controlled desiccation, precise superficial point coagulation |
Spray Coagulation | 120 W | Non-contact coagulation of broad bleeding surfaces |
Bipolar Output
Waveform | Rated Power | Typical Use |
|---|---|---|
Bipolar Coagulation | 120 W | Precise desiccation, no patient return electrode required |
Bipolar Cutting | 120 W | Division of soft tissue such as fascia and omentum |
The circular mode screen is the control centre of the LS10D:
Automatic recognition — identifies the attached instrument and loads the matching output mode.
Clear mode display — shows the active function and output power at a glance.
Power adjustment — set and fine-tune power quickly.
Volume control — adjust audible feedback to suit the operating room.
Separate readouts — monopolar and bipolar power levels shown independently.
A full range of accessories is available to match the LS10D to the procedure:
Vessel-sealing instruments — open and laparoscopic sealing forceps with various jaw profiles.
Electrosurgical pencils and electrodes — reusable and disposable options for cutting and coagulation.
Bipolar forceps and cables — for precision coagulation and bipolar cutting.
Foot switches — monopolar and bipolar, hand-switch and footswitch control supported.
Patient return electrodes — adult and paediatric, single and dual types, with cable.
Electrode cables — for connection to the monopolar output port.
Isolated RF output with leakage-current control.
Patient return electrode monitoring to verify safe contact with the patient.
Start-up self-check with audible and visual error indication.
Memory function restores previously used settings on power-up.
Audible completion signal for vessel-sealing mode.
Operating temperature +5 °C to +40 °C, humidity ≤ 80%.
General & Gastrointestinal Surgery — Gastrectomy, colectomy, splenectomy, thyroidectomy, axillary dissection.
Gynaecology — Hysterectomy, oophorectomy, myomectomy, LEEP.
Urology — TURP, prostatectomy, nephrectomy, cystectomy.
Orthopaedic & Arthroscopic Surgery — Soft-tissue division and haemostasis.
ENT, Neurosurgery & Plastic Surgery — Precision work requiring limited lateral thermal effect.